Myalarm V-LCD1 Manuel d'instructions Page 196

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 336
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 195
PC/VDT PROGRAMMING - AUXILIARY OUTPUTS
9-190
System 2 Installation / Programming Manual
As discussed above, various system events can be assigned to operate auxiliary outputs. Some
events will trigger outputs only locally on the unit on which they occur, while other events will trigger
outputs both on the unit they occur and on the master as well. Bear in mind, however, that the unit on
which an event occurs and the master may be one in the same unit (i.e., it happened on the master
and not on a slave).
If programmed to trigger outputs, events deemed important to system reliability or security (in our
opinion here at Corby) trigger both on the unit on which they occur and on the master. Other “lesser”
events trigger outputs only locally on the unit on which they occur.
The table below specifies the behavior of each of the triggerable events.
Event Type Local Only Both Master and Slave
System Reset X
AC Off X
AC On X
Door Ajar X
Door Closed X
Forced Entry X
Valid User X
Inv X
PIN Error X
Sched Error X
Request to Exit X
AP Error X
Door Perm X
Mem Clear X
Zone On X
Zone Off X
Slave Down X
Net Noise X
Vue de la page 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 335 336

Commentaires sur ces manuels

Pas de commentaire